Abstract
Magnetostrictive composites are of considerable interest for real-time remote force sensing and structural health monitoring. In this paper, we introduce a new procedure for modeling the magnetic field induced by an external load applied on an epoxy-based composite material filled with Terfenol-D particles. This model is based on an assumed sequence of physical processes that occur at the microscopic scale, and it includes both domain switching and magnetization rotation. The modeling procedure is demonstrated on a problem relevant for load sensing applications in which the magnetostrictive composite is subjected to a uniaxial compression. Comparison of the calculated and experimental results strengthens the validity of the assumed sequence of physical processes and provides valuable insights important for application developments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.