Abstract
Abstract This paper describes the set-up and calibration of the tagging system of the GDH-Experiment at the accelerator facility E lsa in Bonn. The system consists of a C-type dipole magnet and a hodoscope of 65 scintillation counters which are operated pairwise in coincidence to form 64 tagging channels. Photons can be tagged in a range of 68–97% of the primary electron energy E0. The energy resolution ranges from 0.2% to 0.6% of E0. The time resolution is better than 165 ps . The system was operated at rates up to 5×10 6 photons/s in the full tagged energy range. The energy dependence of the photon definition probability was determined using several different methods and was found to agree well with calculations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.