Abstract
TPS7051 Background: The prognosis for adults with relapsed or refractory BCP-ALL is poor. MRD+ is the strongest predictor of relapse. Blinatumomab, a CD3/CD19-directed BiTE® (bispecific T-cell engager) molecule, is an effective treatment for patients with MRD+.1 Blinatumomab is administered as a continuous intravenous infusion (cIV) 28 days per cycle. Severe adverse events (AEs) such as cytokine release syndrome (CRS) and neurologic toxicity (NT) may occur; thus, hospitalization is recommended for the first 3 days of cycle 1 and the first 2 days of cycle 2 for MRD+ patients. However, the incidence of severe AEs is low in MRD+ BCP-ALL patients (CRS: 2%, NT: 13%).1 We believe that with the use of effective digital monitoring devices, blinatumomab can be safely administered for the entire 28-day cIV cycle as an outpatient. Methods: Adult patients (n = 45) with BCP-ALL in complete remission and MRD+ (≥0.1% blasts) are being enrolled at 25 planned treatment sites, endpoint: grade ≥3 AE during monitoring (Amgen NCT04506086). Patient suitability for blinatumomab and outpatient monitoring is established. Patients will receive 2-4 cycles of blinatumomab. Cycles are initiated in the outpatient setting, digital monitoring devices activated and attached, and patients sent home. Once home, patients set up the home hub and real-time remote data transfer to the healthcare professional (HCP) begins. The devices are worn continuously, 24 hours a day for the first 3 days of cycle 1 and the first 2 days of cycle 2 only. Devices: Current Health’s Wearable Monitoring System (CHWMS) is an FDA-cleared platform for wireless and wearable health monitoring of patients at home. The CHWMS provides continuous oxygen saturation, respiratory rate, and heart rate; an axillary temperature sensor is worn and provides continuous temperature. Patients manually measure blood pressure every 3-6 hours around the clock. Patients have an integrated mobile device (tablet) to initiate contact with the HCP if needed. HCP/designee has a mobile device (smart phone) and receives vital signs as a constant live feed transmitted from the CHWMS device. The CHWMS platform generates a loud audible alert based on pre-specified vital sign alarming thresholds or if there is an interruption in data transfer. HCP may initiate direct audio and video contact with the patient, assess the patient’s condition, and make an appropriate intervention. HCP may also initiate patient contact in the absence of an alert. Patients are required to have a caregiver present during the entire period of outpatient monitoring. Patients have a full set of replacement devices as well as a 24/7 hotline for device support. Trial enrollment is underway. This study may generate feasibility data on the effectiveness of home monitoring during blinatumomab infusion in patients with MRD+ BCP-ALL. 1Gökbuget, Blood, 2018. Clinical trial information: NCT04506086.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.