Abstract

This work proposed a novel approach based on principal component analyses (PCAs) to monitor the very early-age hydration of self-compacting concrete (SCC) with varying replacement ratios of fly ash (FA) to cement at 0%, 15%, 30%, 45%, and 60%, respectively. Based on the conductance signatures obtained from electromechanical impedance (EMI) tests, the effect of the FA content on the very early-age hydration of SCCs was indicated by the predominant resonance shifts, the statistical metrics, and the contribution ratios of principal components, quantitatively. Among the three, the PCA-based approach not only provided robust indices to predict the setting times with physical implications but also captured the liquid-solid transition elongation (1.5 h) during the hydration of SCC specimens with increasing FA replacement ratios from 0% to 45%. The results demonstrated that the PCA-based approach was more accurate and robust for quantitative hydration monitoring than the conventional penetration resistance test and the other two counterpart indices based on EMI tests.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call