Abstract
The stability of reset control systems has been mainly studied for the feedback interconnection of reset compensators with linear time-invariant systems. This work gives a stability analysis of reset compensators in feedback interconnection with passive nonlinear systems. The results are based on the passivity approach to L 2 -stability for feedback systems with exogenous inputs, and the fact that a reset compensator will be passive if its base compensator is passive. Several examples of full and partial reset compensations are analyzed, and a detailed case study of an in-line pH control system is given.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.