Abstract

This paper presents a material relative permittivity extraction technique based on three measurements of two identical coaxial lines, terminated by a short-circuit configuration. The test cells have the same geometric dimensions but various lengths. The most extended fixture is partially filled with the sample under test to be measured in the scanned frequency [6–20] GHz. The measurement methodology is based on the use of the fixture form factor. The accuracy of the relative permittivity parameter is better than 5% throughout the frequency range. All tested samples have been compared with the two transmission-line technique results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.