Abstract

A computational fluid dynamic study was carried out to investigate airflow pattern, temperature, and humidity profile at different levels in the drying chamber. Good agreement was obtained with published experimental data. The effects of operating pressure, heat loss from the chamber wall and inlet air conditions on the gas flow pattern, droplet trajectories, and overall dryer performance also were investigated. Results are presented and discussed in terms of the gas velocity, temperature, and humidity profiles within the chambers. The volumetric evaporation values, heat transfer intensity, and thermal energy consumption per unit evaporation rate were computed and compared for drying of a 42.5% solids solution in a spray chamber 2.215 m in diameter with a cylindrical top section 2.005 m high and a bottom cone 1.725 m high. Wall regions subject to formation of undesirable deposits are also identified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.