Abstract
This paper investigates the three dimensional flow field and organism concentration in a UV disinfection channel. The modified P-1 model is newly adopted to solve the UV intensity field. This modified P-1 model for radiative transfer can yield an accurate light intensity for even complicated geometries. The effect of UV light intensity on the disinfection of microorganisms has been considered in the species equation. Differently from existing literatures, this study has used the Euler method for the calculation of both the flow field and the concentration of organisms. The CFD modeling results are compared with existing experimental data [1] for a UV channel, which shows outstanding agreement. The effects of inlet velocity, absorption coefficients of lamps quartz and water on the disinfection efficiency are investigated. With a smaller inlet velocity and smaller absorption coefficients, higher disinfection efficiency has been obtained. The current CFD model has the capability to predict the performance of UV disinfection channels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.