Abstract

In Chubu University, bellows pipes are applied to absorb the heat shrink as a part of straight pipes for superconducting power transmission lines (SC PT). In conventional SC PT systems, SC cables are put in corrugated pipe. Pressure drop of the liquid nitrogen flow in bellows and corrugated pipes are analyzed by a fluid-analysis software. Pressure drop per unit length in the bellows and corrugated pipes is respectively 2.6 and 3.7 times that in the straight pipes. Pressure drop in the bellows is smaller than that in the corrugated pipes. Therefore, bellows are preferable for the DC-SC PT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.