Abstract

Two stage ac–dc converters consisting of front-end power factor correction ac–dc boost converter followed by an isolated dc–dc converter form the industry workhorses for powering network servers, telecom, and other dc loads. For safe and uninterrupted operation during sudden intermittences in power supplied from the ac mains, the ac–dc power converter should be able to supply the load with constant dc output voltage in order to prevent them from unwanted resetting or in other words exhibit sufficient hold-up time (HUT) operation. This paper proposes a novel dc–dc nonresonant full-bridge converter with extended HUT capability and reduced dc-link storage capacitance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.