Abstract

The double-wave method is widely used in ferroelectric measurements to eliminate the effects of conductance and capacitance components while preserving the ferroelectric domain contribution. However, in polycrystalline ferroelectric material, the assumption of the evolution of domains by the double-wave method no longer applies due to the domain back switch of de-field, and the domain contribution calculated by the current subtraction method is also problematic. Therefore, we proposed a new method to calculate the charge contribution of conductance and eliminate the conductance interference in the hysteresis loop. Finally, the feasibility of this new method is verified in many typical polycrystalline ferroelectric materials. This work provides a path for the study of ferroelectric properties of some high conductivity materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.