Abstract

A technique to enhance the purity of accelerated radioactive ion beams for decay studies is presented. The technique requires a 3MeV=nucleon beam and a transmission ionization chamber. The gas pressure in the multi-anode ionization chamber is adjusted so that high-Z components of the beam are ranged out in the gas transmitting the more exotic, low-Z components to the measuring station. Initial tests with a radioactive 120Ag and 120In mixed beam indicate at least a factor of 5 relative enhancement of the 120Ag decay transitions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.