Abstract

Mass detection sensitivity and measuring accuracy of resonant mass sensors are mainly dependent on the analyte position, the resonant frequency, and the effective mass of the cantilever. For measuring concentrated masses or particles, a novel mass sensor incorporating V-shaped cross section cantilever was proposed by locating the analyte at predefined positions for both improving the mass detecting sensitivity and reducing the measuring deviation. The theoretical model for analyzing the mass detection sensitivity was established. With the same geometric dimension, the proposed sensor's sensitivities obtained theoretically and experimentally are 6.75×104 and 6.34×104 Hz/g, which are nearly 2.20 times as great as that of the custom made cantilever with a rectangular cross section. Thus, the feasibility of the proposed sensitivity improving method was adequately validated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.