Abstract
This work reports on a novel method involving reverse-phased ultra-high performance liquid chromatography (UHPLC) plus a spectrophotometric photodiode array/fluorescence (FLR) detection system for determining the concentration of equol and major soy isoflavones (daidzein and genistein) in human urine. The proposed method was validated in terms of its linearity, sensitivity, accuracy (recovery) and precision (intra- and inter-day repeatability). The isoflavone profiles of urine samples from a group of menopausal women following oral soy isoflavone supplementation were determined and compared. Screening for equol-producer status was accomplished with high sensitivity (detection limit of the FLR detector 2.93nM). The method involves a short chromatographic run time compared to conventional HPLC methods while allowing for the simultaneous and reliable quantification of daidzein, genistein and equol in human urine. It also allows for the rapid screening of multiple urine samples when testing for equol production status and checking patient adherence to isoflavone treatment regimens.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.