Abstract
Lift-off variation causes errors in eddy-current measurement of metallic plate thickness. In this paper, we designed a triple-coil sensor operating as two coil pairs and in a multifrequency mode. It is found that the difference in their peak frequencies (the frequency when the imaginary part of the inductance reaches peak) is linearly proportional to the plate thickness but virtually immune to lift-off variations. Mathematical derivation, simulation, and experimental results verified the validity of the methodology.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Instrumentation and Measurement
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.