Abstract

BackgroundEndotracheal tube (ETT) placement is a critical procedure for newborns that are unable to breathe. Inadvertent esophageal intubation can lead to oxygen deprivation and consequent permanent neurological impairment. Current standard-of-care methods to confirm ETT placement in neonates (auscultation, colorimetric capnography, and chest x-ray) are time consuming or unreliable, especially in the stressful resuscitation environment. Point-of-care ultrasound (POCUS) of the neck has recently emerged as a powerful tool for detecting esophageal ETTs. It is accurate and fast, and is also easy to learn and perform, especially on children.MethodsThis will be an observational diagnostic accuracy study consisting of two phases and conducted at the Aga Khan University Hospital in Karachi, Pakistan. In phase 1, neonatal health care providers that currently perform standard-of-care methods for ETT localization, regardless of experience in portable ultrasound, will undergo a two-hour training session. During this session, providers will learn to detect tracheal vs. esophageal ETTs using POCUS. The session will consist of a didactic component, hands-on training with a novel intubation ultrasound simulator, and practice with stable, ventilated newborns. At the end of the session, the providers will undergo an objective structured assessment of technical skills, as well as an evaluation of their ability to differentiate between tracheal and esophageal endotracheal tubes. In phase 2, newborns requiring intubation will be assessed for ETT location via POCUS, at the same time as standard-of-care methods. The initial 2 months of phase 2 will include a quality assurance component to ensure the POCUS accuracy of trained providers. The primary outcome of the study is to determine the accuracy of neck POCUS for ETT location when performed by neonatal providers with focused POCUS training, and the secondary outcome is to determine whether neck POCUS is faster than standard-of-care methods.DiscussionThis study represents the first large investigation of the benefits of POCUS for ETT confirmation in the sickest newborns undergoing intubations for respiratory support.Trial registrationClinicalTrials.gov Identifier: NCT03533218. Registered May 2018.

Highlights

  • Endotracheal tube (ETT) placement is a critical procedure for newborns that are unable to breathe

  • Neonatal deaths account for 75% of all neonatal deaths, and preventing these deaths depends on attention to the causes of death that are unique to the first week of life, birth asphyxia [3], which accounts for 23% of global neonatal deaths [1]

  • Unsuccessful intubation can lead to devastating consequences, and one of the most common reasons for intubation failure of is esophageal placement of an ETT [26]

Read more

Summary

Methods

This will be an observational diagnostic accuracy study consisting of two phases and conducted at the Aga Khan University Hospital in Karachi, Pakistan. In phase 1, neonatal health care providers that currently perform standardof-care methods for ETT localization, regardless of experience in portable ultrasound, will undergo a two-hour training session. During this session, providers will learn to detect tracheal vs esophageal ETTs using POCUS. In phase 2, newborns requiring intubation will be assessed for ETT location via POCUS, at the same time as standard-of-care methods. The primary outcome of the study is to determine the accuracy of neck POCUS for ETT location when performed by neonatal providers with focused POCUS training, and the secondary outcome is to determine whether neck POCUS is faster than standard-of-care methods

Discussion
Background
Methods/design
Objective
Findings
Full Text
Published version (Free)