Abstract
This paper proposes a novel method, called Ringdown Time-Domain Vector Fitting (RTD-VF), for estimating electromechanical modes in interconnected power systems. Such a method authentically extends, to the context of ringdown analysis, the well known Time-Domain Vector Fitting (TD-VF) method, which has already been successfully applied within other power systems areas. The proposed method is based on a state-space discretization framework which enables ringdown events to be effectively estimated when described as artificial unit impulse responses. Moreover, RTD-VF completely avoids the necessity to perform discrete Fourier transforms (DFTs) of ringdown data sequences. Three case studies are used to validate the proposed method. One of the examples considers a synthetic test signal, whereas the other two case studies consider actual ringdown data sets extracted from the North American Eastern Interconnection (NAEI) system and from the Brazilian Interconnected Power (BIP) system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.