Abstract

We evaluated the potential of cardiac magnetic resonance (CMR)-derived strain to assess aortic valve (AV) annulus deformation during the cardiac cycle in regurgitant and well-functioning AVs. Four patients with severe aortic regurgitation and seven healthy controls underwent CMR. Assessment of longitudinal strain was performed by hypothesizing the AV annulus would be the left ventricle in long-axis orientation. Longitudinal strain of the segments belonging to the muscular and fibrous AV annulus was weighted and averaged to obtain regional values (RLS). Comparison of RLS between regurgitant and well-functioning AVs showed a considerably different deformation of the muscular AV annulus (i.e., median RLS: 4.18 % [patients] vs. -10.41 % [controls], p = .024). The fibrous AV annulus demonstrated comparable deformational changes in both groups. CMR-derived strain allows for quantification of AV annulus deformation during the cardiac cycle and shows an altered RLS in the muscular AV annulus in patients with severe aortic regurgitation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.