Abstract

There has been a rapid expansion of multi-modal imaging techniques in tomography. In biomedical imaging, patients are now regularly imaged using both single photon emission computed tomography (SPECT) and x-ray computed tomography (CT), or using both positron emission tomography and magnetic resonance imaging (MRI). In non-destructive testing of materials both neutron CT (NCT) and x-ray CT are widely applied to investigate the inner structure of material or track the dynamics of physical processes. The potential benefits from combining modalities has led to increased interest in iterative reconstruction algorithms that can utilize the data from more than one imaging mode simultaneously. We present a new regularization term in iterative reconstruction that enables information from one imaging modality to be used as a structural prior to improve resolution of the second modality. The regularization term is based on a modified anisotropic tensor diffusion filter, that has shape-adapted smoothing properties. By considering the underlying orientations of normal and tangential vector fields for two co-registered images, the diffusion flux is rotated and scaled adaptively to image features. The images can have different greyscale values and different spatial resolutions. The proposed approach is particularly good at isolating oriented features in images which are important for medical and materials science applications. By enhancing the edges it enables both easy identification and volume fraction measurements aiding segmentation algorithms used for quantification. The approach is tested on a standard denoising and deblurring image recovery problem, and then applied to 2D and 3D reconstruction problems; thereby highlighting the capabilities of the algorithm. Using synthetic data from SPECT co-registered with MRI, and real NCT data co-registered with x-ray CT, we show how the method can be used across a range of imaging modalities.

Highlights

  • Biomedical imaging modalities, such as single photon emission computed tomography (SPECT) and positron emission tomography (PET) provide information about the distribution of radioisotopes and tracers in living tissue

  • Since we perform the maximum-likelihood expectation maximization (MLEM) step for every penalty function we reduce our notation for reconstruction methods with penalties to diffusion tensor (DT), Bowsher method (BM), and combined DT (CDT)

  • We have shown a novel approach for incorporating available additional information from different imaging modalities into diffusion filtering processes

Read more

Summary

Introduction

Biomedical imaging modalities, such as single photon emission computed tomography (SPECT) and positron emission tomography (PET) provide information about the distribution of radioisotopes and tracers in living tissue. These distributions allow physicians to determine certain chemical properties of the tissue [1]. The major drawback of the functional modalities is low signal-to-noise ratio and low spatial resolution of the reconstructed images. Modalities such as x-ray CT and magnetic resonance imaging (MRI) are able to achieve a superior spatial resolution of anatomical structure. The same sample volume can be scanned using multiple imaging systems, such as x-ray CT and neutron CT (NCT)

Methods
Findings
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call