Abstract
Airway stabilization in neonates with occipital encephalocele (OE) is critical during surgery or if they develop hypoxic-respiratory failure. Endotracheal intubation can be challenging due to difficulty in positioning the head in a patient with large occipital mass. We describe a novel technique for positioning neonates with large OE using a commonly used hospital apparatus which facilitated appropriate positioning of the baby and successful endotracheal intubation with ease and no additional staff.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.