Abstract
In this work, a fusiform Au/MIL-53(Fe) catalyst was used to construct a chemiluminescence (CL) kit for the sensitive and rapid detection of thrombin (THR). The porous silica microspheres encapsulated with luminol in holes by thrombin aptamer (THR-APT/Luminol/SPSiO2) and the fusiform Au/MIL-53(Fe) modified with thrombin aptamer complementary chains (Au/MIL-53(Fe)-SSDNA) were prepared. Then, a CL kit for THR detection was constructed by using the prepared composites. When thrombin is added to the reaction system, it binds to its aptamer (THR-APT) to open the holes of SPSiO2, which cause luminol and Au/MIL-53(Fe) release. Released luminol enters the detection system and triggers the reaction of luminol–H2O2–NaOH with the catalyst of Au/MIL-53(Fe), and produces a CL signal. The detection limit and the linear range of the kit were 4.7 × 10−15 M and 1.5 × 10−14 – 3.5 × 10−10 M, respectively. The CL kit also showed high stability, selectivity and reproducibility, and was successfully applied to the determination of THR in serum samples. Therefore, the proposed method for detecting THR has great application potential in the diagnosis of blood-related disease markers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.