Abstract

AbstractThe voltammetric behavior of clopidogrel bisulfate (CLO), an antiplatelet agent, was investigated for the first time in the literature on a cathodically pretreated boron‐doped diamond electrode (CP‐BDDE) using cyclic (CV) and square‐wave voltammetry (SWV). It was observed an anodic peak for CLO, suitable for analytical purposes, at about 1.15 V (vs. Ag/AgCl (3.0 mol L−1 KCl)) by CV in Britton‐Robinson buffer solution (pH 5.0). On the physical‐chemical characterization of the interface phenomena, it was proved that electrode reaction of the analyte was controlled by a diffusion process. At optimized square‐wave parameters (pulse amplitude of 60 mV, frequency of 30 Hz and scan increment of 3 mV), the obtained analytical curve was linear for the CLO concentration range from 0.60 to 60.0 μmol L−1, with a detection limit of 0.60 μmol L−1. The simple, rapid and greener analytical method, based on CP‐BDDE electrochemical sensor, was successfully applied in real samples (pharmaceuticals and urine).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call