Abstract

This paper proposes and implements a novel rotor position sensorless technique for PM AC motor drives, which allows acceleration from standstill and can operate under various practical operating conditions including transient speed changes. The technique developed here relies on the measurement of the phase voltages and currents of the motor. It uses the incremental values of flux linkage, and the back-EMF functions to estimate incremental rotor position. Using a phase-locked loop (PLL) algorithm, an internal closed-loop correction algorithm can correct rotor position estimation drift, which may be due to the motor parameter variations or measurement inaccuracies. The method is implemented in closed-loop using a digital signal processor (DSP), and details of the implementation are provided in the paper. To demonstrate accuracy, robustness and reliability of the position estimation scheme, the paper presents a number of real-time experimental results, including dynamic operating conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.