Abstract

Abstract Background Annular rupture is a catastrophic complication of Transcatheter Aortic Valve Implantation, more commonly seen with balloon expandable valves. Size selection and deployment of these valves often presents a serious challenge as prosthesis oversizing increases the risk of rupture, while undersizing results in greater paravalvular regurgitation (PVR). Current deployment protocols are volume-regulated and susceptible to undesired prosthesis over or under-expansion. Laplace's Law demonstrates that the stress exerted on the aortic wall is determined by both the valve area and internal pressure during deployment. Yet the issue of balloon pressure during deployment has been thus far ignored. Purpose In this feasibility study, we aimed to develop a novel pressure-regulated deployment method that allows optimising apposition between valve and annulus, while preventing significant tissue injury and rupture. Methods We analysed a cohort of 278 consecutive patients with severe aortic stenosis and intermediate-severe surgical risk who underwent TAVI using Sapien 3 valves. This included 88 patients (32%) considered at high risk of annular rupture based on accepted factors such as moderate-severe subannular calcification. A pressure gauge was connected to the apparatus and in each case the valve was deployed until reaching a pre-determined pressure limit. In earlier cases lower pressures of 4–4.5atm were used to establish safety, while in later cases pressure limit was increased to maximum of 7atm. In some patients post-dilatation was performed to improve angiographic regurgitation. Using a biomechanical application of Laplace's Law, the estimated annular wall stress was calculated for each case and assessed against recorded complications such as annular rupture, PPM insertion, new LBBB and PVR on post-procedure TTE. Based on these analyses we then determined the optimal pressure limit for each available valve size. Results Distribution of deployment pressures and associated estimated wall stress are shown in attached Figure. 1 case of annular rupture (0.4%) occurred in high risk patient at 3.81MPa. Wall stress levels >3.0MPa were associated with reduced rates of post dilatation (13% vs 37%, p<0.001) and ≥mild PVR (10.7% vs 20%, p=0.093). In patients (148) with estimated wall stress between 3–3.8MPa rates of new PPM and LBBB were 7.4% and 8.1%, respectively. Greater wall stress was not associated with increased new PPM/LBBB risk. Therefore, we suggest the optimal deployment pressure limit to minimise risk of rupture, rates of post-dilatation and clinically significant PVR is: 6atm for 23mm valves, 5.5atm for 26mm valves and 5atm for 29mm valves. Conclusion Pressure-regulated deployment strategy is a reproducible, safe and effective method for balloon expandable TAVI, alleviating concerns of valve oversizing in high risk patients. Further trials are needed to validate this novel method and compare it with current volume-regulated techniques. Abstract Figures Funding Acknowledgement Type of funding source: None

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.