Abstract
A new method for the preparation of large size porous anodes has been developed, called counter-gravity infiltration; and four kinds of porous Pb–Ag anodes with different pore sizes were prepared. The anodes were tested in a pilot plant for 24 days with the electrolyte drawn from the zinc electrowinning plant. The results show little impact on the electrowinning system. However, the weight of the porous anode was 60% less than the flat plate anode; the corrosion rates were only one-fifth of the flat plate anode; and the pass rate of cathode zinc almost reached 100%. The cell voltages associated with each porous anode were lower than the flat plate anode with no difference in current efficiencies. This reduced the energy consumption by up to 78 kWh/t-Zn for the porous anode with a pore size of 1.6–2.0 mm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.