Abstract

Dorsal plate fixation is commonly used for first metatarsophalangeal joint (1st MTPJ) arthrodesis and plate design continues to evolve. A new staple compression plate (SCP) design attempts to utilize the continuous compression of a nitinol staple across the fusion site while simultaneously providing the stability of a dorsal locked plate. Herein, we compare the radiographic, clinical, and patient-reported outcomes of 1st MTPJ joint arthrodesis using 2 dorsal locking plate constructs including a novel SCP construct. Forty-four patients who underwent 1st MTPJ arthrodesis between 2016 and 2020 were retrospectively evaluated. There were 2 group cohorts. Group 1 cohort included 23 patients who received a CrossRoads Extremity SCP, and Group 2 cohort included 21 patients who received a Stryker dorsal locking precontoured titanium plate (LPP). All patients were evaluated with radiographs, Patient-Reported Outcomes Measures Information System (PROMIS) outcome scores, and Foot Function Index (FFI). The complication and union rates did not vary between groups with a fusion rate of 95.7% in the SCP group and 90.5 % in the LPP group. Similarly, we found no significant differences in PROMIS or FFI scores between the SCP and LPP plates. Use of either dorsal locking plate construct for 1st MTPJ arthrodesis was associated with high union rates and comparable functional outcomes. As locked plate technology continues to evolve for 1st MTPJ arthrodesis, it is important that clinical outcomes are reported. Level IV.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call