Abstract

Insulation failures are one of the most common failure modes of ac motors, particularly high-voltage motors. Online monitoring of insulation health of ac motors is important for preventing unexpected outages and minimizing the associated financial losses, particularly in critical applications. Previously, an online ground-wall insulation monitoring technique has already been proposed for six-lead ac motors. In this paper, a novel online ground-wall insulation monitoring scheme is proposed for inverter-fed ac motors. This approach is based on measurement of common-mode insulation leakage current for online capacitance and dissipation factor (C/DF) monitoring. The proposed technique can be applied to both three-lead and six-lead ac motors and can also be extended to monitor the insulation health of the cable connecting the inverter and the motor. The proposed technique is demonstrated in the lab environment and correlated with standard offline C/DF measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.