Abstract

This paper presents a new non-isolated asymmetrical buck converter. The transformer is used to extend the extremely low duty-cycle of a conventional buck converter. The turn-off loss can be significantly reduced due to the extension of duty-cycle and there is no turn-on loss owing to zero-voltage turn-on condition. At the same time, the voltage stress over the synchronous rectifier (SR) MOSFETs is also reduced. Therefore, the reverse recovery losses of the body diode can also be reduced. Furthermore, MOSFETs with the lower voltage rating and lower R <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ds(on)</sub> can be used to reduce the conduction loss further. To further reduce the turn-off loss above the switching frequency of 1MHz, current-source gate driver can be also applied to this topology. A prototype at switching frequency of 1MHz was implemented and the preliminary experimental results verify the functionality of the new circuit.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.