Abstract

A time-domain electromagnetic interference (TDEMI) measurement system allows to reduce the measurement time by several orders of magnitude in comparison with conventional systems. This will reduce the costs of compliance tests considerably. In this work, a novel multiresolution time-domain EMI (MRTDEMI) measurement system is presented. The MRTDEMI exhibits several channels with limiters, amplifiers and analog-to-digital converters (ADCs). The amplitude range of the signal is subdivided into several intervals. In each interval, the analog-to-digital conversion is performed with a discretisation proportional to the width of the interval. The signal-to-noise ratio (SNR) of the MRTDEMI measurement system compared with a conventional TDEMI measurement system for transient signals is enhanced by at least 50 dB. Measurements were performed in the frequency range from 30 MHz-1GHz.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.