Abstract

In this paper we present the world’s first micropump entirely fabricated using a 3D direct manufacture process based on microstereolithography. The device employs a single pneumatically actuated membrane, with flow rectification provided by a nozzle/diffuser arrangement. A maximum flow rate of just over 2,000 μl/min was achieved with a pneumatic pressure of 2 PSIG and a stroke rate of 96 Hz. The fabrication of actuator components using stereolithography apparatus (SLA) is a potentially major step towards the realisation of low-cost, disposable, rapid manufactured and fully integrated micro total analysis systems (μTAS).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.