Abstract

The aim of this study was to improve image quality of statistical reconstruction by using the 2-D system matrix (SM) trained with an artificial neural network (ANN). For training the ANN SM (SM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ANN</sub> ), the inputs of ANN, the digital images, were generated by scanning the mini-deluxe cold spot phantom at ten different orientations using an optical scanner (resolution: 0.01 mm/pixel). The desired outputs were generated by acquiring the projection data with the corresponding angles using the micro positron emission tomography (microPET) R4. In the ANN method, the ADALINE network with a bias vector and a momentum term were used. Moreover, a multiline-source phantom and a four-segment phantom were scanned to obtain the spatial resolutions and the quantitative accuracy for comparison, respectively. A rat FDG microPET image was acquired to compare the difference between the results reconstructed by the microPET's built-in 2-D-ordered subsets expectation maximization algorithm (OSEM), OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">microPET</sub> , OSEM by Monte Carlo simulated SM, OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">SMd</sub> , and OSEM by the SM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ANN</sub> , OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ANN</sub> . In the multiline-source experiment, the resolutions of OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">microPET</sub> measured at center, 10, and 20 mm from the center were 1.61, 1.78, and 2.30 mm, respectively. The resolutions of OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">SMd</sub> and OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ANN</sub> were 1.24, 1.68, and 1.87, and 1.28, 1.62, and 1.72 mm, respectively. In the results of the four-segment phantom, the sum of absolute error of the truth versus the values reconstructed by OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">microPET</sub> , OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">SMd</sub> , and OSEM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ANN</sub> were 1085.53, 913.48, and 435.02, respectively. By interpreting the results of the evaluation, the image quality reconstructed by the SM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ANN</sub> is better than that reconstructed by the original SM. The results indicated that SM can be updated toward ideal SM using ANN for statistical reconstruction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.