In this paper, the mechanism of flow‐accelerated corrosion (FAC) and FAC rate prediction model are investigated. A modified MIT model is obtained by illustrating the relationship between CPF thickness and porosity with CPF stress based on fluid structure interaction (FSI) numerical simulation. The results reveal that the effect of fluid on CPF strength gradually increased with increasing of velocity, thereby increasing Tresca stress and deformation. CPF thickness gradually decreased with increasing stress and decreasing pH. CPF porosity gradually increased with increasing Tresca stress; however, porosity change became smaller when stress reached a certain value. CPF porosity is gradually reduced with increasing temperature. Finally, FAC rate is proportional to Tresca stress and temperature and is inversely proportional to pH. The calculation results of the modified MIT model agree with the experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.