Abstract
Although heat pump clothes dryers offer the potential to save a significant amount of energy as compared to conventional vented electric dryers; they are prone to air leakage that can limit their efficiency gain. This study serves to develop a novel method of quantifying leakage, and to determine specific leakage locations in the dryer drum and air circulation system. The method follows an ASTM (American Society of Testing and Materials) standard, which is used to determine air leakage area in a household ventilation system through fan pressurization. This ASTM method is adapted to the dryer system, and the leakage area is determined by an analysis of the leakage volumetric flow - pressure relationship. The procedure presents a framework that determines and quantifies major components contributing to leakage in HPCDs. The novel method can improve component design features, resulting in more efficient HPCD systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.