Abstract

Ultrasound is widely used in the diagnosis and follow-up of chronic arthritis. We present an evaluation of a novel automatic ultrasound diagnostic tool based on image recognition technology. Methods used in developing the algorithm are described elsewhere. For the purpose of evaluation, we collected 140 ultrasound images of metacarpophalangeal and proximal interphalangeal joints from patients with chronic arthritis. They were classified, according to hypertrophy size, into four stages (0–3) by three independent human observers and the algorithm. An agreement ratio was calculated between all observers and the standard derived from results of human staging using κ statistics. Results was significant in all pairs, with the highest p value of 3.9 × 10–6. κ coefficients were lower in algorithm/human pairs than between human assessors. The algorithm is effective in staging synovitis hypertrophy. It is, however, not mature enough to use in a daily practice because of limited accuracy and lack of color Doppler recognition. These limitations will be addressed in the future.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.