Abstract
Using the conventional volumetric method in unsteady-state relative permeability measurements for unconventional gas reservoirs, such as coal and gas shale, is a significant challenge because the movable water volume in coal or shale is too small to be detected. Moreover, the dead volume in the measurement system adds extra inaccuracy to the displaced water determination. In this study, a low-field nuclear magnetic resonance (NMR) spectrometer was introduced into a custom-built relative permeability measurement apparatus, and a new method was developed to accurately quantify the displaced water, avoiding the drawback of the dead volume. The changes of water in the coal matrix and cleats were monitored during the unsteady-state displacement experiments. Relative permeability curves for two Chinese anthracite and bituminous coals were obtained, matching the existing research results from the Chinese coalbed methane area. Moreover, the influences of confining pressure on the shape of the relative permeability curve were evaluated. Although uncertainties and limits exist, the NMR-based method is a practical and applicable method to evaluate the gas/water relative permeability of ultra-low permeability rocks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.