The wire bonding of chips with copper interconnects is a challenging issue. The present study develops a method in which the substrates are stored in a temperature and humidity controlled environment such that copper oxide films of appropriate thickness are formed on the substrate prior to the gold-copper thermosonic bonding process. It is shown that this film can be removed during the bonding process, hence rendering the wire bonding process feasible without the requirement for an inert gas environment or the use of metallic cap layers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.