Abstract

BackgroundAnteroposterior (AP) pelvic radiographs remain the standard for pre- and postoperative imaging during total hip arthroplasty (THA), despite the known limitation of plain films, including the inability to adequately account for distortion caused by variations in pelvic orientation such as pelvic tilt. The purpose of this study was to develop a reliable method for correcting pelvic tilt on AP pelvic radiographs in patients undergoing THA.MethodsCT scans from 20 patients/cadaver specimens (10 male, 10 female) were used to create 3D renderings, from which synthetic radiographs of each pelvis were generated. For each pelvis, 13 synthetic radiographs were generated, showing the pelvis at between -30° and 30° of pelvic tilt, in 5° increments. On each image, eight unique parameters/distances were measured to determine the most appropriate parameters for the calculation of pelvic tilt. The most reliable and accurate of these parameters was determined via regression analysis and used to create gender-specific nomograms from which pelvic tilt measurements could be calculated. The accuracy and reliability of the nomograms and correction method were subsequently validated using both synthetic radiographs (n=50) and stereoradiographic images (n=58).ResultsOf the eight parameters measured, the vertical distance between the superior margin of the pubic symphysis and the transischial line (PSTI) was determined to be the most reliable (r=-0.96, ICC=0.94). Using that parameter and applying the associated nomograms to 50 synthetic radiographs of random pelvic tilt, the mean difference between the actual pelvic tilt and that calculated using the correction method was 0.1°±5.1° (p=0.98, r=0.96). In 58 stereoradiographic images, the mean difference between actual and measured pelvic tilt was -0.2°±6.4° (p=0.74, r=0.77). The pooled results indicate no significant difference between actual (2.2°±13.9°) and measured pelvic tilt (2.1°±14.3°, p=0.93, r=0.91). No significant differences were noted based on gender.ConclusionsOur method of correcting for pelvic tilt using the vertical distance from the pubic symphysis to the transischial line provides a reliable method for correcting for pelvic tilt on AP pelvic radiographs.

Highlights

  • Anteroposterior (AP) pelvic radiographs remain the standard for pre- and postoperative imaging during total hip arthroplasty (THA), despite the known limitation of plain films, including the inability to adequately account for distortion caused by variations in pelvic orientation such as pelvic tilt

  • Our method of correcting for pelvic tilt using the vertical distance from the pubic symphysis to the transischial line provides a reliable method for correcting for pelvic tilt on AP pelvic radiographs

  • Anteroposterior (AP) pelvic radiographs remain the standard of care imaging modality for pre- and postoperative assessment during total hip arthroplasty (THA) [1,2], due largely to their ease of use, costeffectiveness, and widespread availability [3,4,5]

Read more

Summary

Introduction

Anteroposterior (AP) pelvic radiographs remain the standard of care imaging modality for pre- and postoperative assessment during total hip arthroplasty (THA) [1,2], due largely to their ease of use, costeffectiveness, and widespread availability [3,4,5] Despite their ongoing use, radiographs are subject to artifacts and are limited by an inability to adequately account for the distortion caused by 3D variations of pelvic orientation such as pelvic tilt, obliquity, and rotation [3,6].

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.