Abstract

3-Acetamidobenzene -1, 2-dicarboxylic acid is a potential genotoxic impurity which gets formed during synthesis of 3- acetamidopthalic anhydride, a Key Starting Material (KSM) for manufacturing of apremilast API. During handling upon exposure to moisture, the anhydride ring of KSM 3-acetamidopthalic anhydride opens to form the acid. Hence Reverse phase HPLC method is not a feasible and robust option for estimation of this impurity. To overcome these problems a normal phase HPLC method is developed and proposed in this research work. Immobilized Chiral pack IA column from Daicel is used for estimation. n-Hexane and isopropyl alcohol in 90:10 (v/v) ratio modified with 0.1% trifluroacetic acid is used as mobile phase. Method is validated as per ICH guidelines. Limit of Detection (LOD) and Limit of Quantification (LOQ) are found to be 0.47 ppm (0.0047%) and 1.42 ppm (0.0142%), respectively. The method is linear over LOQ to 150%. Recovery is within limits (80-120%). Method is robust for parameters like mobile phase composition, flow rate, wavelength changes and column oven temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.