Abstract

A fuzzy PD plus repetitive control scheme for single-phase 400 Hz CVCF inverters is presented. The principle of the proposed control scheme is to use a repetitive controller, which performs satisfactorily in steady state, while a fuzzy PD controller improves transient performance whenever the system exhibits an oscillatory or overshoot behavior. The fuzzy PD controller preserves the simple linear structure of the conventional PD controller yet enhances its self-tuning control capability. The repetitive controller is synthesizing to minimize low-order harmonic distortion. Thus, the fuzzy PD controller and repetitive controller can be combined to take advantage of their positive attributes. The control scheme is implemented using a TI TMS320F240 DSP in a 400 Hz 6 kW prototype. Simulation and experimental results prove that the proposed control scheme can achieve not only low THD during steady-state operation but also fast transient response subject to load step change.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.