Abstract

Purpose: To present a novel, full-digital protocol for the design and fabrication of implant-supported monolithic translucent zirconia crowns cemented on customized hybrid abutments. Methods: The present retrospective clinical study was based on data from patients who had been treated with single Morse-taper connection implants (Exacone®, Leone Implants, Florence, Italy) and were prosthetically restored with monolithic translucent zirconia crowns, cemented on customized hybrid abutments. The full-digital protocol (SCAN-PLAN-MAKE-DONE®) consisted of 8 phases: (1) intraoral scan of the implant position with scanbody; (2) computer-assisted design (CAD) of the individual abutment (saved as “supplementary abutment design” in external folder) and temporary crown; (3) milling of the individual zirconia abutment and of the temporary polymethyl-methacrylate (PMMA) crown, with extraoral cementation of the zirconia abutment on the relative titanium bonding base, to generate an individual hybrid abutment; (4) clinical application of the individual hybrid abutment and cementation of the temporary PMMA crown; (5) two months later, intraoral scan of the individual hybrid abutment in position; (6) CAD of the final crown with margin line design on the previously saved “supplementary abutment design”, superimposed on the second scan of the abutment in position; (7) milling of the final crown in monolithic translucent zirconia, sintering, and characterization; and (8) clinical application of the final crown. All patients were followed for a period of 1 year. The primary outcomes of this study were the marginal adaptation of the final crown (checked clinically and radiographically), the quality of occlusal and interproximal contact points at delivery, and the aesthetic integration; the secondary outcomes were the 1-year survival and success of the implant-supported restoration. An implant-supported restoration was considered successful in the absence of any biological or prosthetic complication, during the entire follow-up period. Results: In total, 25 patients (12 males, 13 females; 26–74 years of age; mean age 51.1 ± 13.3 years) who had been restored with 40 implant-supported monolithic translucent zirconia crowns were included in this study. At delivery, the marginal adaptation was perfect for all crowns. However, there were occlusal issues (2/40 crowns: 5%), interproximal issues (1/40 crowns: 2.5%), and aesthetic issues (1/40 crowns: 2.5%). The overall incidence of issues at delivery was therefore 10% (4/40 crowns). At 1 year, one implant failed; thus the survival of the restorations was 97.5% (39/40 crowns in function). Among the surviving implant-supported restorations, three experienced complications (one loss of connection between the hybrid abutment and the implant, one decementation of the zirconia abutment, and one decementation of the zirconia crown). The success of restorations amounted to 92.4%. Conclusions: The restoration of single Morse-taper connection implants with monolithic translucent zirconia crowns cemented on customized hybrid abutments via the novel SCAN-PLAN-MAKE-DONE® full-digital protocol seems to represent a reliable treatment option. However, further studies on a larger number of patients and dealing with different prosthetic restorations (such as implant-supported fixed partial prostheses) are needed to confirm the validity of this protocol.

Highlights

  • The intraoral scanner (IOS) represents an important innovation in the world of dentistry, able to transform conventional prosthetic [1,2], surgical [3], and orthodontic [4] workflows.IOS allows one to capture impressions of the dental arches of patients without having to use conventional impression materials with relative trays, but using only a light source that is projected onto the teeth to be scanned [1,2,5]

  • 25 patients (12 males, 13 females; age range 26–74 years of age, mean age 51.1 ± 13.3 years, median age 48 years; confidence interval (CI) 95% 45.9–56.3 years) who had been restored with 40 implant-supported monolithic translucent zirconia crowns (25 maxilla, 15 mandible; 12 premolars, 28 molars) were included in this study

  • The patient was still satisfied with the color and asked for the final restoration to be cemented without further chromatic changes, or delay

Read more

Summary

Introduction

IOS allows one to capture impressions of the dental arches of patients without having to use conventional impression materials (polyether, polyvinylsiloxane, alginate) with relative trays, but using only a light source (a structured light grid or, more rarely, a laser) that is projected onto the teeth to be scanned [1,2,5]. The deformation that this light grid undergoes at impact with the teeth is captured by powerful cameras and reworked by the scanning software, which generates a cloud of points [2,5]. The plaster models are eliminated with the possibility of saving space in the dental office because the acquired files are saved in the computer and can be sent to the dental laboratory by e-mail, without additional costs [12]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call