Abstract

In this work, we demonstrate a flexible multi-pin plasma generator with movable electrodes, which can change the shape of the electrode array freely, and then provide a large-area uniform plasma for the treatment of surfaces of different shapes. Discharge characteristics including U–I waveforms and discharge images and sterilization performance under three different electrode configurations (flat–flat, flat–curve, curve–curve) are investigated. Very similar results are acquired between the flat–flat configuration and the curve–curve configuration, which is much better than that under flat–curve configuration. This flexible multi-pin plasma generator offers a simple method to treat different irregularly shaped surfaces uniformly with a single device. Moreover, this device provides a foundation for developing a self-adaption large-scale uniform plasma generator by further introducing automatic adjustment of the position of every electrode driven by motors with discharge current feedback in the following study. Thus it will promote the applications of atmospheric-pressure cold plasmas significantly.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.