Abstract
To improve the fault-tolerant operation ability of open-winding PMSM (OW-PMSM) system, a novel fault-tolerant topology and deadbeat control method for single phase open-circuit fault is proposed. Compared with the conventional fault-tolerant topology of the OW-PMSM system with single phase open-circuit, this new topology can reduce the number of bridge arm from 4 to 3. Two switching devices and their drivers are saved while ensuring the control performance. Finally, simulation results validate the effectiveness of the proposed topology and the control method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.