Abstract

With the growing cyber-infrastructure of smart grids, the threat of cyber-attacks has intensified, posing an increased risk of compromised communication links. Of particular concern is the false data injection (FDI) attack, which has emerged as a highly dangerous cyber-attack targeting smart grids. This paper addresses the limitations of the variable dummy value model proposed in the authors previous work and presents a novel defense methodology called the nonlinear function-based variable dummy value model for the AC power flow network. The proposed model is evaluated using the IEEE 14-bus test system, demonstrating its effectiveness in detecting FDI attacks. It has been shown that previous detection techniques are unable to detect FDI attacks, whereas the proposed method is shown to be successful in the detection of such attacks, guaranteeing the security of the smart grid’s measurement infrastructure.