Abstract

Developing a rapid, sensitive, and efficient analytical method for the trace-level determination of highly concerning antibiotic ciprofloxacin (CIP) is desirable to guarantee the safety of human health and ecosystems. In this work, a novel electrochemical aptasensor based on polyethyleneimine grafted reduced graphene oxide and titanium dioxide (rGO/PEI/TiO2) nanocomposite was constructed for ultrasensitive and selective detection of CIP. Through the in-situ electrochemical oxidation of Ti3C2Tx nanosheets, TiO2 nanosheets with good electrochemical response were prepared in a more convenient and eco-friendly method. The prepared TiO2 nanosheets promote charge transferring on electrode interface, and [Fe(CN)6]3-/4- as electrochemical active substance can be electrostatically attracted by rGO/PEI. Thus, electrochemical detection signal of the aptasensor variates a lot after specific binding with CIP, achieving working dynamic range of 0.003–10.0 μmol L−1, low detection limit down to 0.7 nmol L−1 (S/N = 3) and selectivity towards other antibiotics. Additionally, the aptasensor exhibited good agreement with HPLC method at 95% confidence level, and achieved good recoveries (96.8–106.3%) in real water samples, demonstrating its suitable applicability of trace detection of CIP in aquatic environment.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call