Abstract
This paper presents a novel current-control-based control strategy, obtained in stationary frame, for a three-phase pulsewidth-modulated AC/DC voltage-source converter. In this control strategy, an error voltage is produced from the comparison of the output DC voltage with a DC reference voltage. This error voltage is then utilized by a proportional plus integral controller to generate a command signal for the input line current amplitude and is automatically controlled to the desired value. Therefore, there is no need to measure the input line currents. Stability analysis of the closed-loop system is made, and the stability region for proportional and integral gains which makes the operating point stable is also found. The resulting closed-loop system not only exhibits good transient response, but also provides sinusoidal line currents and unity power factor, both in the rectifying and regenerating modes. Experimental results are presented and compared with simulations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.