Abstract

In this paper we introduce a novel control method of a three-phase PWM inverter with output LC filter. The transfer function of LC filter is the same as that of second order LPF(low pass filter) except that it has zero damping ratio. A simple method to implement second order LPF with damping ratio is adding resistor in series with reactor. But the series resistor cannot be used in real high power system because it consumes lots of energy being proportion to square of conducted current. So, proposed control strategy utilizes the measured capacitor voltages and voltage references of inverter to damp LC filter resonance instead of a series resistor. The overall transfer function is the same as second order LPF and damping ratio is also controllable via control variables. Experimental waveforms are presented to verify LC filter control algorithm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.