This paper investigates the use of dummy components along with heat sources on a substrate board. Three-dimensional steady state laminar forced convection cooling of a discrete heat source array in a vertical channel is studied numerically and experimentally. The main objective of this study is to find the optimal distribution of seven heat sources with dummy components to minimize the substrate temperature. Air cooling of circuit boards populated with heat sources is modeled and simulated to present heat transport in combination with the fluid flow. This work also aims to study the effect of substrate thermal conductivity on fluid flow and heat transfer characteristics by using substrate boards of different thermal conductivities. The experiments are performed without dummy components and with 2, 4, 6, 8 dummy components at three different air velocities of 0.6, 1.0, 1.4 m/s. A correlation for θ in terms of Re, and k∗ is obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.