Abstract

ObjectiveThe aim of this study was to propose a new computer based method for measuring acetabular angles on hip radiographs and to assess its practicality, sensitivity and reliability for acetabular angle measurement. MethodsA total of 314 acetabulum were assessed on 157 pelvic X-ray images. Acetabular angles were measured with both the conventional method (Method 1) and our proposed method (Method 2). All the Acetabular Index (AI) angle, Acetabular Angle (AA) and Acetabular Center (ACM) angle were measured with both methods. ResultsThe mean AI angle for Method 1 is 11.02° ± 2.7° and the mean AI angle for Method 2 is 10.08° ± 1.88°, the mean AA angle for Method 1 is 39.5° ± 5.3° and the mean AA angle for Method 2 is 39.36° ± 4.68°, the mean ACM angle for Method 1 is 50.5° ± 6.01° and the mean ACM angle for Method 2 is 55.42° ± 12.43°. ConclusionOur novel automated method appear to be reliable and practical for acetabular angle measurement on hip radiographs. Level of EvidenceLevel III, Diagnostic study

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.