Abstract

Background and aims In recent years, focus on assessing descending pain modulation or conditioning pain modulation (CPM) has emerged in patients with chronic pain. This requires reliable and simple to use bed-side tools to be applied in the clinic. The aim of the present pilot study was to develop and provide proof-of-concept of a simple clinically applicable bed-side tool for assessing CPM. Methods A group of 26 healthy volunteers participated in the experiment. Pressure pain thresholds (PPT) were assessed as test stimuli from the lower leg before, during and 5min after delivering the conditioning tonic painful pressure stimulation. The tonic stimulus was delivered for 2min by a custom-made spring-loaded finger pressure device applying a fixed pressure (2.2kg) to the index finger nail. The pain intensity provoked by the tonic stimulus was continuously recorded on a 0-10cm Visual Analog Scale (VAS). Results The median tonic pain stimulus intensity was 6.7cm (interquartile range: 4.6-8.4cm) on the 10cm VAS. The mean PPT increased significantly (P=0.034) by 55±126kPa from 518±173kPa before to 573±228kPa during conditioning stimulation. When analyzing the individual CPM responses (increases in PPT), a distribution of positive and negative CPM responders was observed with 69% of the individuals classified as positive CPM responders (increased PPTs=anti-nociceptive) and the rest as negative CPM responders (no or decreased PPTs=Pro-nociceptive). This particular responder distribution explains the large variation in the averaged CPM responses observed in many CPM studies. The strongest positive CPM response was an increase of 418kPa and the strongest negative CPM response was a decrease of 140kPa. Conclusions The present newly developed conditioning pain stimulator provides a simple, applicable tool for routine CPM assessment in clinical practice. Further, reporting averaged CPM effects should be replaced by categorizing volunteers/patients into anti-nociceptive and pro-nociceptive CPM groups. Implications The finger pressure device provided moderate-to-high pain intensities and was useful for inducing conditioning stimuli. Therefore, the finger pressure device could be a useful bed-side method for measuring CPM in clinical settings with limited time available. Future bed-side studies involving patient populations are warranted to determine the usefulness of the method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.