Abstract
Aiming at the problem that the USBL installation error is difficult to accurately calibrate in the complex underwater environment. In this paper, based on smooth variable structure and unscented Kalman filter, a novel USBL installation error calibration algorithm is proposed. Firstly, the nonlinear system model of USBL installation error based on the filter estimation principle is analyzed. On this basis, the USBL installation error calibration algorithm based on the principle of unscented Kalman filter is given. Secondly, in view of the shortcomings of the UKF calibration algorithm, smooth variable structure is introduced, and a novel algorithm combining smooth variable structure and UKF is proposed. Finally, the effectiveness of the algorithm proposed in this paper is verified by simulation and river test. The results show that the algorithm proposed in this paper can accurately and stably estimate the USBL installation error parameters when the underwater acoustic signal is disturbed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Instrumentation and Measurement
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.